| Technical Data | NB58G001 - Two levels | NB58G002 - Stretched form | |||
| Equipment | 2 Process Zones, length 1.6 m each, with Dust Covers, Automatic Looping Unit, PLC-controlled, Steel Frame; | 2 Process Zones, length 1.6 m and 1 m, with Dust Covers, Automatic Looping Unit, PLC-controlled, Steel Frame; | |||
|
| ||||
| Preferred application |
| ||||
| Process area | 1 | 2 | 1 | 2 | |
| Recommended wire diameter (mm) (AWG) | ~ 0.2 (32) – 1.5 (15) | ~ 0.2 (32) – 6 (3) | |||
| Max. friction force (N) | ~ 150 | ~ 70 | ~ 150 | ~ 70 | |
| Cord-tension at pay-off-side (N) | 5 – 100 | 5 – 40 | 5 – 100 | 5 – 40 | |
| Max. cord tension at take-up-side (N) | 250 | 80 | 250 | 80 | |
| Adjustable speed of HELICORD (cm/min.) | 10 – 120 | ||||
| Control | All parameters controlled by PLC and displayed on operator panel | ||||
| Power supply | 16 Amp. 3 P+N+E 380 V 50 Hz | ||||
| Power consumption (W) | Max. 1,000 | ||||
| Operational conditions | Ambient temperature(°C)(°F) | Clean air for electrical cabinet: max. 40 (104) Environment: max. 50 (122) | |||
| Rel. air humidity (%) | 80 (not condensing) | ||||